Substitutes in Non-Mechanical Heat Transfer Systems
Substitutes are reviewed on the basis of ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptable and unacceptable substitutes are updated several times each year. A chronological list of SNAP updates is also available.
Unacceptable substitutesNote: SNAP-related information published in the Federal Register takes precedence over all information on this page.
Acceptable Substitutes for CFCs (class I ODS) in Non-Mechanical Heat Transfer Systems
| Substitute (Name Used in the Federal Register) | Trade Name | Refrigerant Being Replaced | Retrofit/ New |
|---|---|---|---|
| Carbon Dioxide | all CFCs | R, N | |
| Water | all CFCs | R, N | |
| Mineral Oil | all CFCs | R, N | |
| Volatile Methyl Siloxanes | all CFCs | R, N | |
| Galden Fluids | all CFCs | R | |
| HFC-236fa | 114 | R, N | |
| HFE-7100 | 11, 12, 113, 114, 115 | R, N | |
| HFC-4310mee | all CFCs | R, N | |
| HFE-7200 | 11, 12, 113, 114, 115 | R, N | |
| Hydrofluoroether 7000 | HFE-7000 | 11, 113 | R, N |
| R-407C | Suva 407C, Klea 407C | 502 | R, N |
| R-422C | ICOR XLT1 | 502 | R, N |
| HCF-245fa | Genetron® 245fa | 11, 113 | R, N |
| KDD6 | KDD6 | 12 | R, N |
| C6 perfluoroketone | NovecTM 649 | 113 | R, N |
Acceptable Substitutes for HCFCs (class II ODS) in Non-Mechanical Heat Transfer Systems
| Substitute (Name Used in the Federal Register) | Trade Name | Refrigerant Being Replaced | Retrofit/ New |
|---|---|---|---|
| HFE-7100 | 22 | R, N | |
| HFC-4310mee | all HCFCs | R, N | |
| ISCEON 59, NU-22, R-417A | ISCEON 59, NU-22 | 22 | R, N |
| HFE-7200 | 22 | R, N | |
| R-422D | ISCEON MO29 | 22 | R, N |
| KDD5, R-438A | ISCEON MO99 | 22 | R, N |
| HCF-245fa | Genetron® 245fa | 21, 141b | R, N |
| R-125/290/134a/600a (55.0/1.0/42.5/1.5) | ICOR AT-22 | 22 | R, N |
| R-422B | XAC1, NU-22B | 22 | R, N |
| R-422C | XLT1 | 22, 402A, 402B, 408A | R, N |
Substitutes for CFCs in Non-Mechanical Heat Transfer Systems Acceptable Subject to Narrowed Use Limits
| Substitute | ODS Being Replaced | Narrowed Use Limit | Retrofit/ New |
|---|---|---|---|
| PFCs (C 3F 8, C 4F 10, C 5F 12, C 5F 11NO, C 6F 14, C 6F 13NO, C 7F 16, C 7F 15NO, C 8F 18, C 8F 17NO, C 9F 21N) | all CFCs | PFCs are only allowed in new systems where a study has demonstrated that no other alternatives are technically feasible due to safety or performance requirements; this study must be kept available for review. | R, N |