Acceptable Substitutes in Ice Skating Rinks
Substitutes are reviewed on the basis of ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptable and unacceptable substitutes are updated several times each year. A chronological list of SNAP updates is also available.
Unacceptable substitutesNote: SNAP-related information published in the Federal Register takes precedence over all information on this page.
Acceptable Substitutes for CFCs (class I ODS) in Ice Skating Rinks
| Substitute (Name Used in the Federal Register) | Trade Name | Refrigerant Being Replaced | Retrofit/ New |
|---|---|---|---|
| HCFC-22 | 12, 502 | R, N | |
| R-401A, R-401B | MP-39, MP-66 | 12 | R |
| R-407A, R-407B | Klea 407A, 407B | 502 | R, N |
| Free Zone (HCFC Blend Delta) | Free Zone / RB-276 | 12 | R, N |
| Freeze 12 | Freeze 12 | 12 | R, N |
| GHG-X4 | GHG-X4, Autofrost, Chill-it | 12, 500 | R, N |
| G2018C | G2018C | 12, 500, 502 | R, N |
| Hot Shot | Hot Shot, Kar Kool | 12, 500 | R, N |
| THR-04 | THR-04 | 502 | R, N |
| Ammonia Vapor Compression | 12, 502 | N | |
| RS-24 (2002 formulation) | 12 | R, N | |
| R-407C | Suva 407K, Klea 407C | 502 | R, N |
| R-420A | Choice R-420A | 12, 500 | R, N |
| R-421B | Choice R421B | 12, 502 | R, N |
| R-426A | RS-24 | 12 | R, N |
| R-422C | ICOR XLT1 | 502 | R, N |
| R-428A | RS-52 | 502 | R, N |
| KDD6 | KDD6 | 12 | R, N |
Key: R = Retrofit Uses, N = New
Uses
Acceptable Substitutes for HCFCs (class II ODS) in Ice Skating Rinks
| Substitute (Name Used in the Federal Register) | Trade Name | Refrigerant Being Replaced | Retrofit/ New |
|---|---|---|---|
| THR-03 | N | ||
| ISCEON 59, NU-22, R-417A | ISCEON 59, NU-22 | R, N | |
| R-410A, R-410B | AZ-20, Suva 9100, Puron | N | |
| R-407C | Suva 9000, Klea 66 | R, N | |
| Ammonia Vapor Compression | N | ||
| Ammonia Absorption | N | ||
| R-404A | HP62 | R, N | |
| RS-44 (2003 formulation) | 22 | R, N | |
| ISCEON 79 | ISCEON 79 | R, N | |
| R-421A | Choice R421A | 22 | R, N |
| R-421B | Choice R421B | 22 | R, N |
| R-422D | ISCEON MO29 | 22 | R, N |
| R-424A | RS-44 | 22 | R, N |
| R-426A | RS-24 | 22 | R, N |
| KDD5, R-438A | ISCEON MO99 | 22 | R, N |
| R-434A | RS-45 | 22 | R, N |
| R-428A | RS-52 | 22 | R, N |
| R-125/290/134a/600a (55.0/1.0/42.5/1.5) | ICOR AT-22 | 22 | R, N |
| R-422B | XAC1, NU-22B | 22 | R, N |
| R-422C | XLT1 | 22, 402A, 402B, 408A | R, N |
Key: R = Retrofit Uses, N = New
Uses