Method 29 - Metals Emissions from Stationary Sources
FREQUENTLY ASKED QUESTIONS (FAQS) for Method 29Is a Teflon probe liner allowed for a Method 29 sampling train?As you know, section 6.1.1 of Method 29 specifies the probe tip and probe liner . It states that materials other than the specified glass are allowed provided they ".. are constructed of materials that are free from contamination and will not interfere with the sample." What this means is that the material should not add to sample and must not retain sample. The latter could be demonstrated by performing a second sample recovery immediately after the normal one. If the analysis yields only a few percent of the first result, then one might reasonably conclude the material is relatively inert and is OK to use.It is always a good idea to provide advance notice to the regulators that will be reviewing/approving the test results of your plans to demonstrate the performance of the alternate liner material. Still have questions on this method? Contact the EMC expert Bill Grimley at grimley.bill@epa.gov . |