Jump to main content.


Other Methods

From the listing below, find the file you would like to download. The available file formats are represented by icons on the right side of the listing. Click on the icon that represents the file format you wish to receive. For an explanation of file formats and their icons, see our TTNWeb File Types.


Method Description

Supporting Information

Method Text

PRE 1 - Draft Method for Direct measurements of Gas Velocity and Volumetric Flowrate Under Cyclonic Flow Conditions
PRE 2 - Particulate (PM Screening) Method.
Particulate (PM Screening) Figure. See PRE-002
PRE 3 - DRAFT Ontario Hydro Method for Mercury in Flue Gas Generated from Coal- Fired Stationary Sources has been superceded by ASTM D6784-02.
PRE 4 - DRAFT Method for Determination of PM10/PM2.5 has been retired and superseded by the promulgation of the revision of Method 201A.
PRE 5 - Determination of Nitrogen Oxide Emissions from Stationary Sources(Ultraviolet Instrumental Analyzer Procedure) (Adobe format).
PRE 6 (Draft Method 311: Appendix A) Method for the Measurement of Cure HAPS from Paints and Coatings (Adobe format).
PRE 7 - Determination of Cyclonic Flow Velocity Components Using a Calculation Approach to Method 2F
PRE 8 - Determination of Visible Emission Opacity from Stationary Sources Using Computer-Based Photographic Analysis Systems. Note: Please note that there is now a more sophisticated method (ASTM D7520-09) for using digital cameras for determining opacity. We strongly encourage you to consider its use in accordance with the applicability as specified in the method. We have also approved ASTM D7520-09 as an alternative to Method 9 under certain conditions; You can see that document here.
PRE 9 - This method has been superseded by the 9/7/07 Direct Final rulemaking for Method 30A
Preliminary Performance Specification 001 (PPS-001) Ammonia CEMS
Other Test Method 10 (OTM 10) - Optical Remote Sensing for Emission Characterization from Non-Point Sources
Other Test Method 11 (OTM 11) - USEPA Method 18 Pre-Survey Procedure for Corn Wet-Milling Facility Emission Sources has been replaced by Method 207, which was promulgated in 2008 (73 FR 30775).
Other Test Method 12 (OTM 12) - Method 25Aap, Protocol for the Source Testing, Analysis, and Reporting of VOC Emissions from Hot Mix Asphalt Plant Dryers
Other Test Method 13 (OTM 13) - Periodic Monitoring Test Method for O2, CO, and NOx (Multi-Gas Portable Optical Bench Instruments)
Other Test Method 14 (OTM 14) --Method for Measuring Isocyanates in Stationary Source Emissions
Other Test Method 15 (OTM 15) - Test Method 28 OWHH for Measurement of Particulate Emissions and Heating Efficiency of Outdoor Wood-Fired Hydronic Heating Appliances
Other Test Method 16 (OTM 16) - Specifications for X-Ray Fluorescence Based Multi-Metals CEMS at Stationary Sources
Other Test Method 17 (OTM 17) - Determination of Metal Concentration in CES' Xact CEMS Stilling Chamber Using Filters and Solid Sorbents with X-Ray Fluorescence Analysis
Other Test Method 18 (OTM 18) - Performance Specifications for a Quantitative Reference Aerosol Generator
Other Test Method 19 (OTM 19) - Determination of Metal Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure)
Other Test Method 20 (OTM 20) - Quality Assurance Requirements for X-Ray Fluorescence Based Multi-Metals CEMS at Stationary Sources
Other Test Method 21 (OTM 21) - Standard Operating Procedure for Generating a Quantitative Multi-Metals Reference Aerosol with CES QAG
Other Test Method 22 (OTM 22) - Specifications and Test Procedures for HCl CEMS at Stationary Sources Note: Facilities or testers preparing to install and operate HCl CEMS should follow the current stakeholder drafts of Performance Specification 18 and Procedure 6, available from Candace Sorrell (sorrell.candace@epa.gov), rather than using OTM 22 or 23. OTM 22 and 23 will be superseded by PS 18 and Procedure 6 once the new performance specification is promulgated.
Other Test Method 23 (OTM 23) - QA/QC Requirements for HCl CEMS at Stationary Sources Note: Facilities or testers preparing to install and operate HCl CEMS should follow the current stakeholder drafts of Performance Specification 18 and Procedure 6, available from Candace Sorrell (sorrell.candace@epa.gov), rather than using OTM 22 or 23. OTM 22 and 23 will be superseded by PS 18 and Procedure 6 once the new performance specification is promulgated.
Other Test Method 24 (OTM 24) - Tracer Gas Protocol for the Determination of Volumetric Flow Rate Through the Ring Pipe of the Xact Multi-Metals Monitoring System
Other Test Method 25 (OTM 25) - HCl Dynamic Spiking Protocol
Other Test Method 26 (OTM 26) - VOC Measurement for the Wood Products Industry
Other Test Method 27 (OTM 27) - Determining PM10 and PM2.5 Emissions from Stationary Sources has been replaced with the revised Method 201A, which was signed by the EPA Administrator on December 1, 2010.
Other Test Method 28 (OTM 28) - Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources has been replaced with the revised Method 202, which was signed by the EPA Administrator on December 1, 2010.
Other Test Method 29 (OTM 29) - Sampling and Analysis of Hydrogen Cyanide Emissions from Stationary Sources
Other Test Method 30 (OTM 30) - Method to Quantify Particulate Matter Emissions from Windblown Dust
Other Test Method 31 (OTM 31) - Guide for Developing a Multi-Metals, Fence-Line Monitoring Plan for Fugitive Emissions Using X-Ray Based Monitors - The appendices for this method can be found here: Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix H
Other Test Method 32 (OTM 32) - Determination of Emissions from Open Sources by Plume Profiling
Other Test Method 34 (OTM 34) - Method to Quantify Road Dust Particulate Matter Emissions from Vehicular Travel on Paved and Unpaved Roads
Other Test Method 35 (OTM 35) - Measurement of PM and Heavy Metals from Arc Welding Processes

File Utilities


Local Navigation


Jump to main content.