- Name of the facility:
Sunoco, Inc.
- Location:
1819 Woodville Road, Oregon, OH 43616
- Distance from the US/Canada border:
Approximately 50 km
- Type/size of the facility:
Petroleum Refinery - 125,000 barrels per day after
the proposed expansion
- Source of emissions:
FCCU, SRU, flare, fugitive equipment leaks, cooling
towers, fuel gas combustion, storage tanks, load racks
- Type of fuel:
Refinery fuel gas, oil and natural gas
- Type/quantity of mass emission rates
Project total emissions increase/decrease, tons/yr
CO 471.56
NOx -418.60
PM10 111.58
SO2 -8,331.56
VOC 50.97
H2SO4 -46.35
Ammonia 107.92
Net Emissions of CO, PM10 and VOC (including
contemporaneous emissions increase/decrease), tons/yr
CO 366.63
PM10 82.94
VOC 30.65
CO & PM10 emissions are subject to PSD review. Facility
netted out of VOC nonattainment new source review.
- Emission control technology
SRU with tail gas treater & incinerator; wet scrubber,
SCR and CO boilers for control of FCCU emissions; refinery
flare; drift elimintaor on new cooling tower; and, ultra-low
NOx burners on CO boilers
- Date permit application received:
April 25, 2006
- Stack height and diameter:
FCCU/CO Boiler scrubber stack: height 199 ft, diameter 10 ft
SRU1: height 150 ft, diameter 3.6 ft
SRU2: height 150 ft, diameter 2.5 ft
Plant 4 flare: height 250 ft, diameter 3 ft
New cooling tower: 6 egress points with height 43 ft, diameter 16ft
- Permit agency's contact name, address, telephone number:
Mike Hopkins
Ohio Environmental Protection Agency
Lazarus Government Center
122 S. Front Street
Columbus, OH 43215
(614) 644-3611