PITTSBURG
(06/013/0012)
SIC:4911 -Electric services
Annual Tons -----------------------> Daily Tons->
Totals: VOC NOx CO SO2 PM10 VOC NOx
94 1676 852 9 5 0.5 8.6
Source Classification Code Totals
Annual Tons -----------------------> Daily Tons->
SCC VOC NOx CO SO2 PM10 VOC NOx SCC Description
10100601 58 1169 722 5 3 0.2 4.7 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
10100604 37 508 131 3 2 0.3 3.9 Ext Comb Boilers;Elec. Gen.;Natural Gas;Tangentially Fired Units
Plant Totals 94 1676 852 9 5 0.5 8.6
Point Level
Annual Tons ------------------> Daily Tons-> Blr.Cap Heatinput hrs/ days/ wks/ hrs/ Seasonal Thruput(%)->
Pointid Stackid VOC NOx CO SO2 PM10 VOC NOx MMBtu/hr MMBtu/hr day wk yr yr Win Spr Sum Fall ST/CNTY/Plantid/pointid
1 001 3 71 38 0 0 0.0 0.9 1417.5 943745 24 7 52 8736 25 25 25 25 06/013/0012 /1
2 001 3 57 42 0 0 0.0 0.5 1417.5 1038287 24 7 52 8736 25 25 25 25 06/013/0012 /2
3 001 1 19 7 0 0 0.0 0.2 1417.5 187666 24 7 52 8736 25 25 25 25 06/013/0012 /3
4 001 2 60 30 0 0 0.0 0.5 1417.5 752522 24 7 52 8736 25 25 25 25 06/013/0012 /4
5 002 28 572 355 3 2 0.1 1.6 2700.0 8767675 24 7 52 8736 25 25 25 25 06/013/0012 /5
6 002 20 390 249 2 1 0.1 1.1 2700.0 6170004 24 7 52 8736 25 25 25 25 06/013/0012 /6
7 003 37 508 131 3 2 0.3 3.9 6700.0 11257123 24 7 52 8736 25 25 25 25 06/013/0012 /7
Plant Totals 94 1676 852 9 5 0.5 8.6
Segment/Process Level
Annual Tons-------------> Daily tons-> Thruput Max.Rate HeatCon Ash Sulfur HeatInput
Pointid Stackid Seg. SCC VOC NOx CO SO2 PM10 VOC NOx scc/yr scc/yr MMBtu/scc % % MMBtu/hr SCC Description
1 001 61 10100601 3 71 38 0 0 0.0 0.9 904.1 1044 943745 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
2 001 61 10100601 3 57 42 0 0 0.0 0.5 1001.0 1037 1038287 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
3 001 61 10100601 1 19 7 0 0 0.0 0.2 174.5 1075 187666 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
4 001 61 10100601 2 60 30 0 0 0.0 0.5 721.0 1044 752522 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
5 002 61 10100601 28 572 355 3 2 0.1 1.6 8452.4 1037 8767675 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
6 002 61 10100601 20 390 249 2 1 0.1 1.1 5930.7 1040 6170004 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang.
7 003 64 10100604 37 508 131 3 2 0.3 3.9 10897.4 1033 11257123 Ext Comb Boilers;Elec. Gen.;Natural Gas;Tangentially Fired Units
Plant Totals 94 1676 852 9 5 0.5 8.6
Stack Level
Pointid Stackid Eff.Hgt Height Dia Temp Flow Velocity Annual tons ----------------> Daily tons->
(ft) (ft) (ft) (°F) (cfs) (ft/s) Lat. Long. VOC NOx CO SO2 PM10 VOC NOx
1 001 916 212 11.51 300 9500.00 91.00 38.0394 121.9011 3 71 38 0 0 0.0 0.9
2 001 916 212 11.51 300 9500.00 91.00 38.0394 121.9011 3 57 42 0 0 0.0 0.5
3 001 916 212 11.51 300 9500.00 91.00 38.0394 121.9011 1 19 7 0 0 0.0 0.2
4 001 916 212 11.51 300 9500.00 91.00 38.0394 121.9011 2 60 30 0 0 0.0 0.5
5 002 1430 450 13.73 285 17283.33 117.00 38.0394 121.9011 28 572 355 3 2 0.1 1.6
6 002 1430 450 13.73 285 17283.33 117.00 38.0394 121.9011 20 390 249 2 1 0.1 1.1
7 003 1904 450 19.99 285 33333.33 106.00 38.0394 121.9011 37 508 131 3 2 0.3 3.9
Plant Totals 94 1676 852 9 5 0.5 8.6
Segment Level - Controls(Not reported for pollutants with no control)
Control Rule
Pointid Stackid Seg. SCC Pollutant Eff. Eff. Primary Control Secondary control
1 001 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
1 001 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
2 001 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
2 001 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
3 001 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
3 001 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
4 001 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
4 001 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
5 002 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
5 002 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
6 002 61 10100601 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
6 002 61 10100601 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
7 003 64 10100604 PM10 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
7 003 64 10100604 PM25 80.0 100 ELECTROSTATIC PRECIPITATOR - MEDIUM EFFICIENCY NO EQUIPMENT
SCC Descriptions
SCC SCC Descriptions SCC Units
10100601 Ext Comb Boilers;Elec. Gen.;Natural Gas;Boilers > 100 MBtu/Hr except Tang. Million Cubic Feet Burned
10100604 Ext Comb Boilers;Elec. Gen.;Natural Gas;Tangentially Fired Units Million Cubic Feet Burned
1996 NET Plant Detail Report 07/13/01
Return to:State/Plant Emission Home Page
|