THE CELOTEX CORPORATION
(17/001/0009)
SIC:2621 -Paper mills
Annual Tons -----------------------> Daily Tons->
Totals: VOC NOx CO SO2 PM10 VOC NOx
42 655 90 4828 57 0.1 1.9
Source Classification Code Totals
Annual Tons -----------------------> Daily Tons->
SCC VOC NOx CO SO2 PM10 VOC NOx SCC Description
10200205 42 632 85 4828 57 0.1 1.7 Ext Comb Boilers;Industrial;Bituminous Coal;Overfeed Stoker
10200602 22 6 1 0.1 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
Plant Totals 42 655 90 4828 57 0.1 1.9
Point Level
Annual Tons ------------------> Daily Tons-> Blr.Cap Heatinput hrs/ days/ wks/ hrs/ Seasonal Thruput(%)->
Pointid Stackid VOC NOx CO SO2 PM10 VOC NOx MMBtu/hr MMBtu/hr day wk yr yr Win Spr Sum Fall ST/CNTY/Plantid/pointid
001 001 21 316 42 2414 28 0.1 0.9 24 7 1 168 25 25 25 25 17/001/0009 /001
002 002 21 316 42 2414 28 0.1 0.9 24 7 1 168 25 25 25 25 17/001/0009 /002
003 000 22 6 1 0.1 24 7 52 8736 50 50 17/001/0009 /003
Plant Totals 42 655 90 4828 57 0.1 1.9
Segment/Process Level
Annual Tons-------------> Daily tons-> Thruput Max.Rate HeatCon Ash Sulfur HeatInput
Pointid Stackid Seg. SCC VOC NOx CO SO2 PM10 VOC NOx scc/yr scc/yr MMBtu/scc % % MMBtu/hr SCC Description
001 001 01 10200205 21 316 42 2414 28 0.1 0.9 11330 5.20 3.23 Ext Comb Boilers;Industrial;Bituminous Coal;Overfeed Stoker
002 002 01 10200205 21 316 42 2414 28 0.1 0.9 11330 5.20 3.23 Ext Comb Boilers;Industrial;Bituminous Coal;Overfeed Stoker
003 000 01 10200602 22 6 1 0.1 1000 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
Plant Totals 42 655 90 4828 57 0.1 1.9
Stack Level
Pointid Stackid Eff.Hgt Height Dia Temp Flow Velocity Annual tons ----------------> Daily tons->
(ft) (ft) (ft) (°F) (cfs) (ft/s) Lat. Long. VOC NOx CO SO2 PM10 VOC NOx
001 001 267 126 5.90 398 642.48 23.50 39.9194 91.4169 21 316 42 2414 28 0.1 0.9
002 002 267 126 5.90 398 642.48 23.50 39.9194 91.4169 21 316 42 2414 28 0.1 0.9
003 000 165 68 4.27 396 390.51 27.27 39.9194 91.4169 22 6 1 0.1
Plant Totals 42 655 90 4828 57 0.1 1.9
Segment Level - Controls(Not reported for pollutants with no control)
Control Rule
Pointid Stackid Seg. SCC Pollutant Eff. Eff. Primary Control Secondary control
001 001 01 10200205 PM10 88.0 100 GRAVITY COLLECTOR - LOW EFFICIENCY NO EQUIPMENT
001 001 01 10200205 PM25 88.0 100 GRAVITY COLLECTOR - LOW EFFICIENCY NO EQUIPMENT
002 002 01 10200205 PM10 88.0 100 GRAVITY COLLECTOR - LOW EFFICIENCY NO EQUIPMENT
002 002 01 10200205 PM25 88.0 100 GRAVITY COLLECTOR - LOW EFFICIENCY NO EQUIPMENT
SCC Descriptions
SCC SCC Descriptions SCC Units
10200205 Ext Comb Boilers;Industrial;Bituminous Coal;Overfeed Stoker Tons Burned
10200602 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr Million Cubic Feet Burned
1996 NET Plant Detail Report 07/13/01
Return to:State/Plant Emission Home Page
|