CS MCCROSSAN CONST
(27/053/0078)
SIC:2951 -Asphalt paving mixtures and b
Annual Tons -----------------------> Daily Tons->
Totals: VOC NOx CO SO2 PM10 VOC NOx
48 54 202 13 77 0.3 0.4
Source Classification Code Totals
Annual Tons -----------------------> Daily Tons->
SCC VOC NOx CO SO2 PM10 VOC NOx SCC Description
30500202 5 4 0 0.0 Mineral Prod;;Asphaltic Concrete;Hot Elevators, Screens, Bins and Mixer
30500203 5 Mineral Prod;;Asphaltic Concrete;Storage Piles
30500204 6 Mineral Prod;;Asphaltic Concrete;Cold Aggregate Handling
30500221 2 4 49 0 58 0.0 0.0
50200101 46 46 153 10 6 0.3 0.3 Solid Waste Disp.;Commercial/Institut.;Incin.: General;Multiple Chamber
Plant Totals 48 54 202 13 77 0.3 0.4
Point Level
Annual Tons ------------------> Daily Tons-> Blr.Cap Heatinput hrs/ days/ wks/ hrs/ Seasonal Thruput(%)->
Pointid Stackid VOC NOx CO SO2 PM10 VOC NOx MMBtu/hr MMBtu/hr day wk yr yr Win Spr Sum Fall ST/CNTY/Plantid/pointid
001 000 2 8 49 3 59 0.0 0.1 6 5 33 990 3 3 46 48 27/053/0078 /001
002 000 46 46 153 10 7 0.3 0.3 6 5 33 990 3 3 46 48 27/053/0078 /002
003 000 11 6 5 33 990 3 3 46 48 27/053/0078 /003
Plant Totals 48 54 202 13 77 0.3 0.4
Segment/Process Level
Annual Tons-------------> Daily tons-> Thruput Max.Rate HeatCon Ash Sulfur HeatInput
Pointid Stackid Seg. SCC VOC NOx CO SO2 PM10 VOC NOx scc/yr scc/yr MMBtu/scc % % MMBtu/hr SCC Description
001 000 01 30500221 2 4 49 0 58 0.0 0.0 288731.0
001 000 02 30500202 4 3 0 0.0 288731.0 Mineral Prod;;Asphaltic Concrete;Hot Elevators, Screens, Bins and Mixer
002 000 01 50200101 46 46 153 10 6 0.3 0.3 30552.0 Solid Waste Disp.;Commercial/Institut.;Incin.: General;Multiple Chamber
002 000 02 30500202 0 0 0 30552.0 Mineral Prod;;Asphaltic Concrete;Hot Elevators, Screens, Bins and Mixer
003 000 01 30500203 5 79820.0 Mineral Prod;;Asphaltic Concrete;Storage Piles
003 000 02 30500204 6 319283.0 Mineral Prod;;Asphaltic Concrete;Cold Aggregate Handling
Plant Totals 48 54 202 13 77 0.3 0.4
Stack Level
Pointid Stackid Eff.Hgt Height Dia Temp Flow Velocity Annual tons ----------------> Daily tons->
(ft) (ft) (ft) (°F) (cfs) (ft/s) Lat. Long. VOC NOx CO SO2 PM10 VOC NOx
001 000 147 34 4.44 230 785.15 50.71 45.0960 93.3838 2 8 49 3 59 0.0 0.1
002 000 142 62 2.87 760 202.16 31.25 45.0960 93.3838 46 46 153 10 7 0.3 0.3
003 000 147 34 4.44 230 785.15 50.71 45.0960 93.3838 11
Plant Totals 48 54 202 13 77 0.3 0.4
Segment Level - Controls(Not reported for pollutants with no control)
Control Rule
Pointid Stackid Seg. SCC Pollutant Eff. Eff. Primary Control Secondary control
001 000 01 30500221 PM10 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
001 000 01 30500221 SO2 75.0 100 WET SCRUBBER - HIGH EFFICIENCY NO EQUIPMENT
001 000 01 30500221 PM25 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
001 000 02 30500202 PM10 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
001 000 02 30500202 SO2 75.0 100 WET SCRUBBER - HIGH EFFICIENCY NO EQUIPMENT
001 000 02 30500202 PM25 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
002 000 01 50200101 PM10 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
002 000 01 50200101 SO2 75.0 100 WET SCRUBBER - HIGH EFFICIENCY NO EQUIPMENT
002 000 01 50200101 PM25 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
002 000 02 30500202 PM10 91.0 100 CENTRIFUGAL COLLECTOR - LOW EFFICIENCY WET SCRUBBER - HIGH EFFICIENCY
002 000 02 30500202 SO2 75.0 100 WET SCRUBBER - HIGH EFFICIENCY NO EQUIPMENT
SCC Descriptions
SCC SCC Descriptions SCC Units
30500202 Mineral Prod;;Asphaltic Concrete;Hot Elevators, Screens, Bins and Mixer Tons Produced
30500203 Mineral Prod;;Asphaltic Concrete;Storage Piles Tons Processed
30500204 Mineral Prod;;Asphaltic Concrete;Cold Aggregate Handling Tons Processed
30500221
50200101 Solid Waste Disp.;Commercial/Institut.;Incin.: General;Multiple Chamber Tons Burned
1996 NET Plant Detail Report 07/13/01
Return to:State/Plant Emission Home Page
|