OWENS-CORNING FIBERGLAS
(27/053/0127)
SIC:2952 -Asphalt felts and coatings
Annual Tons -----------------------> Daily Tons->
Totals: VOC NOx CO SO2 PM10 VOC NOx
3 7 2 0 4 0.0 0.0
Source Classification Code Totals
Annual Tons -----------------------> Daily Tons->
SCC VOC NOx CO SO2 PM10 VOC NOx SCC Description
10200501 0 0 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil
10200602 0 4 0 0 0 0.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
10200603 0 1 0 0 Ext Comb Boilers;Industrial;Natural Gas;Less Than 10 MMBtu/Hr
30500102 3 1 4 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating
39000589 0 0 In-Process Fuel Use;;Distillate Oil;General
39000689 0 3 0 0 In-Process Fuel Use;;Natural Gas;General
Plant Totals 3 7 2 4
Point Level
Annual Tons ------------------> Daily Tons-> Blr.Cap Heatinput hrs/ days/ wks/ hrs/ Seasonal Thruput(%)->
Pointid Stackid VOC NOx CO SO2 PM10 VOC NOx MMBtu/hr MMBtu/hr day wk yr yr Win Spr Sum Fall ST/CNTY/Plantid/pointid
001 000 0 2 0 0 0 0.0 24 7 52 8736 25 25 23 27 27/053/0127 /001
001 001 1 24 7 52 8736 25 25 23 27 27/053/0127 /001
002 000 0 0 0 0 0 24 7 52 8736 27 24 23 26 27/053/0127 /002
002 001 1 24 7 52 8736 25 25 23 27 27/053/0127 /002
003 000 0 0 0 8.0 24 7 52 8736 25 25 25 25 27/053/0127 /003
003 002 1 8.0 24 7 52 8736 25 25 25 25 27/053/0127 /003
004 000 1 0 1 8.0 24 7 35 5880 25 25 25 25 27/053/0127 /004
004 002 1 8.0 24 7 52 8736 25 25 25 25 27/053/0127 /004
005 000 1 0 1 8.0 24 5 43 5160 25 25 25 25 27/053/0127 /005
006 000 1 0 1 8.0 24 7 21 3528 25 25 25 25 27/053/0127 /006
008 000 0 0 0 24 7 52 8736 25 25 25 25 27/053/0127 /008
008 004 1 24 7 52 8736 25 25 25 25 27/053/0127 /008
009 000 0 0 0 0 2.0 24 7 52 8736 25 25 25 25 27/053/0127 /009
010 000 0 0 24 7 52 8736 25 25 25 25 27/053/0127 /010
011 000 0 0 0 0 0 24 7 52 8736 25 25 25 25 27/053/0127 /011
014 000 0 0 0 3.0 24 7 52 8736 25 25 25 25 27/053/0127 /014
Plant Totals 3 7 2 4
Segment/Process Level
Annual Tons-------------> Daily tons-> Thruput Max.Rate HeatCon Ash Sulfur HeatInput
Pointid Stackid Seg. SCC VOC NOx CO SO2 PM10 VOC NOx scc/yr scc/yr MMBtu/scc % % MMBtu/hr SCC Description
001 000 01 10200501 0 0 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil
001 000 02 10200602 0 2 0 0 0 0.0 72.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
001 001 A1 10200501 0 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil
001 001 B1 10200602 1 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
002 000 3 10200603 0 0 0 0 Ext Comb Boilers;Industrial;Natural Gas;Less Than 10 MMBtu/Hr
002 000 01 10200501 0 0 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil
002 000 02 10200602 0 0 2.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
002 001 A1 10200501 0 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil
002 001 B1 10200603 1 Ext Comb Boilers;Industrial;Natural Gas;Less Than 10 MMBtu/Hr
003 000 01 39000689 0 0 0 7.0 In-Process Fuel Use;;Natural Gas;General
003 002 A1 39000689 1 In-Process Fuel Use;;Natural Gas;General
004 000 01 30500102 1 0 1 29017.0 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating
004 002 A1 30500102 1 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating
005 000 01 30500102 1 0 1 29017.0 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating
006 000 01 30500102 1 0 1 29016.0 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating
008 000 01 39000689 0 0 0 4.0 In-Process Fuel Use;;Natural Gas;General
008 004 A1 39000689 1 In-Process Fuel Use;;Natural Gas;General
009 000 01 39000689 0 0 0 0 3.0 In-Process Fuel Use;;Natural Gas;General
010 000 01 39000589 0 0 2.0 0.50 In-Process Fuel Use;;Distillate Oil;General
011 000 01 39000589 0 0 In-Process Fuel Use;;Distillate Oil;General
011 000 02 39000689 0 0 0 0 7.0 In-Process Fuel Use;;Natural Gas;General
014 000 01 39000689 0 0 0 8.0 In-Process Fuel Use;;Natural Gas;General
Plant Totals 3 7 2 4
Stack Level
Pointid Stackid Eff.Hgt Height Dia Temp Flow Velocity Annual tons ----------------> Daily tons->
(ft) (ft) (ft) (°F) (cfs) (ft/s) Lat. Long. VOC NOx CO SO2 PM10 VOC NOx
001 000 166 74 3.96 395 367.03 29.80 45.0430 93.3008 0 2 0 0 0 0.0
001 001 36 15 2.80 550 40.95 6.65 45.0430 93.3008 1
002 000 165 68 4.27 396 390.51 27.27 45.0430 93.3008 0 0 0 0 0
002 001 36 15 2.80 550 40.95 6.65 45.0430 93.3008 1
003 000 173 62 4.10 373 487.84 36.95 45.0430 93.3008 0 0 0
003 002 81 26 1.30 700 128.33 96.68 45.0430 93.3008 1
004 000 115 37 3.45 268 411.98 44.07 45.0430 93.3008 1 0 1
004 002 81 26 1.30 700 128.33 96.68 45.0430 93.3008 1
005 000 115 37 3.45 268 411.98 44.07 45.0430 93.3008 1 0 1
006 000 115 37 3.45 268 411.98 44.07 45.0430 93.3008 1 0 1
008 000 173 62 4.10 373 487.84 36.95 45.0430 93.3008 0 0 0
008 004 128 50 3.80 390 293.74 25.90 45.0430 93.3008 1
009 000 173 62 4.10 373 487.84 36.95 45.0430 93.3008 0 0 0 0
010 000 267 69 5.19 339 1140.08 53.89 45.0430 93.3008 0 0
011 000 267 69 5.19 339 1140.08 53.89 45.0430 93.3008 0 0 0 0 0
014 000 173 62 4.10 373 487.84 36.95 45.0430 93.3008 0 0 0
Plant Totals 3 7 2 4
Segment Level - Controls(Not reported for pollutants with no control)
Control Rule
Pointid Stackid Seg. SCC Pollutant Eff. Eff. Primary Control Secondary control
004 000 01 30500102 VOC 97.0 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
004 000 01 30500102 PM10 97.5 100 NO EQUIPMENT NO EQUIPMENT
004 000 01 30500102 CO 99.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
004 000 01 30500102 PM25 97.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
005 000 01 30500102 VOC 97.0 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
005 000 01 30500102 PM10 97.5 100 NO EQUIPMENT NO EQUIPMENT
005 000 01 30500102 CO 99.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
005 000 01 30500102 PM25 97.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
006 000 01 30500102 VOC 97.0 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
006 000 01 30500102 PM10 97.5 100 NO EQUIPMENT NO EQUIPMENT
006 000 01 30500102 CO 99.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
006 000 01 30500102 PM25 97.5 100 DIRECT FLAME AFTERBURNER NO EQUIPMENT
SCC Descriptions
SCC SCC Descriptions SCC Units
10200501 Ext Comb Boilers;Industrial;Distillate Oil;Grades 1 and 2 Oil 1000 Gallons Burned
10200602 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr Million Cubic Feet Burned
10200603 Ext Comb Boilers;Industrial;Natural Gas;Less Than 10 MMBtu/Hr Million Cubic Feet Burned
30500102 Mineral Prod;;Asphalt Roofing Manufacture;Asphalt Blowing: Coating Tons Asphalt Processed
39000589 In-Process Fuel Use;;Distillate Oil;General 1000 Gallons Burned
39000689 In-Process Fuel Use;;Natural Gas;General Million Cubic Feet Burned
1996 NET Plant Detail Report 07/13/01
Return to:State/Plant Emission Home Page
|