SUPERIOR PLATING
(27/053/0312)
SIC:3471 -Plating and polishing
Annual Tons -----------------------> Daily Tons->
Totals: VOC NOx CO SO2 PM10 VOC NOx
0 9 2 0 0 0.0 0.0
Source Classification Code Totals
Annual Tons -----------------------> Daily Tons->
SCC VOC NOx CO SO2 PM10 VOC NOx SCC Description
10200602 8 2 0 0 0.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
10201002 0 0 0 Ext Comb Boilers;Industrial;Liquified Petro (LPG);Propane
Plant Totals 9 2
Point Level
Annual Tons ------------------> Daily Tons-> Blr.Cap Heatinput hrs/ days/ wks/ hrs/ Seasonal Thruput(%)->
Pointid Stackid VOC NOx CO SO2 PM10 VOC NOx MMBtu/hr MMBtu/hr day wk yr yr Win Spr Sum Fall ST/CNTY/Plantid/pointid
001 000 0 0 24 7 52 8736 25 25 25 25 27/053/0312 /001
002 000 4 1 0 0 0.0 24 7 52 8736 25 25 25 25 27/053/0312 /002
003 002 4 1 0.0 24 7 52 8736 25 25 25 25 27/053/0312 /003
Plant Totals 9 2
Segment/Process Level
Annual Tons-------------> Daily tons-> Thruput Max.Rate HeatCon Ash Sulfur HeatInput
Pointid Stackid Seg. SCC VOC NOx CO SO2 PM10 VOC NOx scc/yr scc/yr MMBtu/scc % % MMBtu/hr SCC Description
001 000 01 10200602 0 0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
002 000 02 10200602 4 1 0 0 0.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
002 000 03 10201002 0 0 0 Ext Comb Boilers;Industrial;Liquified Petro (LPG);Propane
003 002 02 10200602 4 1 0.0 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr
003 002 03 10201002 0 0 Ext Comb Boilers;Industrial;Liquified Petro (LPG);Propane
Plant Totals 9 2
Stack Level
Pointid Stackid Eff.Hgt Height Dia Temp Flow Velocity Annual tons ----------------> Daily tons->
(ft) (ft) (ft) (°F) (cfs) (ft/s) Lat. Long. VOC NOx CO SO2 PM10 VOC NOx
001 000 165 68 4.27 396 390.51 27.27 44.9930 93.2663 0 0
002 000 165 68 4.27 396 390.51 27.27 44.9930 93.2663 4 1 0 0 0.0
003 002 54 30 2.50 350 64.99 13.24 44.9930 93.2663 4 1 0.0
Plant Totals 9 2
Segment Level - Controls(Not reported for pollutants with no control)
Control Rule
Pointid Stackid Seg. SCC Pollutant Eff. Eff. Primary Control Secondary control
SCC Descriptions
SCC SCC Descriptions SCC Units
10200602 Ext Comb Boilers;Industrial;Natural Gas;10-100 MMBtu/Hr Million Cubic Feet Burned
10201002 Ext Comb Boilers;Industrial;Liquified Petro (LPG);Propane 1000 Gallons Burned
1996 NET Plant Detail Report 07/13/01
Return to:State/Plant Emission Home Page
|