Archived List of Cleaner Hydronic Heaters
Phase 1 models are no longer considered "qualified" under the Program after March 31, 2010. Use of permanent labels and hang tags for these models must be discontinued on units manufactured after that date.
Below are 3 lists of cleaner burning hydronic heaters that qualified for the EPA voluntary program. The first table is for models that qualified for the Phase 1 orange tag for "year round" use (about 70 percent cleaner than unqualified models). Please note that although the tag is calculated for year round use, some jurisdictions may not allow "year round" use (i.e., not during summer for just hot water rather than heat). The second table is for models that qualified for the Phase 1 orange tag for "heating season use only." These emissions are calculated as if the model is only used during the heating season. Please note that some jurisdictions do not allow models that only qualify for "heating season use only" because their emissions would be greater if they are used year round.
The third table is archived Phase 2 models that are no longer manufactured, the expiration date has expired, or no longer meet the current emissions level.
TABLE 1
Phase 1 Orange Tag "Year Round" Models
Manufacturer | Model Name & Number |
Heat Output Rating (1) |
Annual Average Emission Rate |
Heat Input (2) Annual Average Emission Level |
Heat Output Annual Average Emission Level |
Highest Individual Test Run |
---|---|---|---|---|---|---|
Pro-Fab Industries Inc. |
Empyre Pro Series 200 |
66,290 BTU/hr |
8.40 grams/hr 0.18 grams/hr/ |
0.182 lbs/million BTU heat input |
0.27 |
18.023 grams/hr |
Central Boiler | E - Classic 2300 |
160,001 BTU/hr |
6.4 grams/hr 0.06 grams/hr/ |
0.20 lbs/million BTU heat input |
0.31 |
17.60 grams/hr |
Piney Manufacturing Limited (Portage and Main) |
Optimizer 250 |
44,519 BTU/hr |
5.33 grams/hr 0.18 grams/hr/ |
0.199 lbs/million BTU heat input |
0.35 |
8.31 grams/hr |
Sequoyah Paradise |
E3300B | 109,528 BTU/hr |
8.1 grams/hr 0.13 grams/hr/ |
0.28 lbs/million BTU heat input |
0.56 |
19.1 grams/hr |
Central Boiler | E - Classic 1200 |
89,613 BTU/hr |
7.5 grams/hr 0.15 grams/hr/ |
0.33 lbs/million BTU heat input |
0.59 |
19.94 grams/hr |
Wood Doctor | Converter | 87,858 BTU/hr |
20.3 grams/hr 0.33 grams/hr/ |
0.30 lbs/million BTU heat input |
0.66 |
41.5 grams/hr |
Heatmor | 400 SSR | 157,784 BTU/hr |
31.3 grams/hr 0.29 grams/hr/ |
0.41 lbs/million BTU heat input |
0.68 |
47.6 grams/hr |
Heatmor | 200 SSR | 71,923 BTU/hr |
20.3 grams/hr 0.42 grams/hr/ |
0.35 lbs/million BTU heat input |
0.76 |
33.4 grams/hr |
Bioheat Resources |
BH500 Eco Energy |
73,067 BTU/hr |
19.07 grams/hr 0.323 grams/hr/ |
0.402 lbs/million BTU heat input |
0.77 |
71.602 grams/hr |
Hardy | KB175 | 66,681 BTU/hr |
16.3 grams/hr 0.31 grams/hr/ |
0.54 lbs/million BTU heat input |
0.87 |
42.7 grams/hr |
Greenwood Technologies (3) | 100 | 18,248 BTU/hr |
15.205 grams/hr 1.090 grams/hr/ |
0.564 lbs/million BTU heat input |
2.046 |
17.80 grams/hr |
Sequoyah Paradise |
E3400 | 101,020 BTU/hr |
21.88 grams/hr 0.42 grams/hr/ |
0.488 lbs/million BTU heat input |
2.37 |
34.77 grams/hr |
1 - Based on 8-hour test for stick wood models and 4-hour test for continuous feed models.
2 - EPA Phase 1 level is 0.60 lbs/million BTU. Emission levels are annual averages unless qualified for heating season use only.
3 - These data are via the "cordwood exception," i.e., according to the ASTM cordwood method in lieu of EPA Method 28 OWHH.
TABLE 2
Phase 1 Orange Tag "Heating Season Only" Models
Manufacturer | Model Name & Number |
Heat Output Rating (1) |
Heating Season Average Emission Rate |
Heat Input (2) Heating Season Average Emission Level |
Heat Output Heating Season Average Emission Level |
Highest Individual Test Run |
---|---|---|---|---|---|---|
Pro-Fab Industries Inc. | Empyre Pro Series 200 |
66,290 BTU/hr |
11.58 grams/hr 0.25 grams/hr/ |
0.186 lbs/million BTU heat input |
0.28 |
18.023 grams/hr |
Piney Manufacturing Limited (Portage and Main) |
Optimizer 250 |
44,519 BTU/hr |
6.59 grams/hr 0.21 grams/hr/ |
0.201 lbs/million BTU heat input |
0.32 |
8.31 grams/hr |
Central Boiler | E - Classic 2300 |
160,001 BTU/hr |
8.6 grams/hr 0.08 grams/hr/ |
0.21 lbs/million BTU heat input |
0.32 |
17.60 grams/hr |
Sequoyah Paradise |
E3300B | 109,528 BTU/hr |
8.5 grams/hr 0.13 grams/hr/ |
0.20 lbs/million BTU heat input |
0.39 |
19.1 grams/hr |
Central Boiler | E - Classic 1200 |
89,613 BTU/hr |
9.1 grams/hr 0.17 grams/hr/ |
0.31 lbs/million BTU heat input |
0.51 |
19.94 grams/hr |
Wood Doctor | Converter | 87,858 BTU/hr |
26.8 grams/hr 0.43 grams/hr/ |
0.30 lbs/million BTU heat input |
0.65 |
41.5 grams/hr |
Alternative Fuel Boilers | EBW150 | 27,441 BTU/hr |
14.14 grams/hr 0.576 grams/hr/ |
0.434 lbs/million BTU heat input |
0.80 |
24.05 grams/hr |
Bioheat Resources |
BH500 Eco Energy |
73,067 BTU/hr |
28.54 grams/hr 0.478 grams/hr/ |
0.479 lbs/million BTU heat input |
0.90 |
71.602 grams/hr |
Aqua-Therm | Omega 100 |
63,807 BTU/hr |
23.80 grams/hr 0.515 grams/hr/ |
0.551 lbs/million BTU heat input |
1.17 |
26.988 grams/hr |
Greenwood Technologies (3) | 100 | 18,248 BTU/hr |
13.643 grams/hr 0.863 grams/hr/ |
0.418 lbs/million BTU heat input |
1.362 |
17.80 grams/hr |
Sequoyah Paradise |
E3400 | 101,020 BTU/hr |
20.10 grams/hr 0.31 grams/hr/ |
0.37 lbs/million BTU heat input |
1.48 |
34.77 grams/hr |
1 - Based on 8-hour test for stick wood models and 4-hour test for continuous feed models.
2 - EPA Phase 1 level is 0.60 lbs/million BTU. Emission levels are annual averages unless qualified for heating season use only.
3 - These data are via the "cordwood exception," i.e., according to the ASTM cordwood method in lieu of EPA Method 28 OWHH.
TABLE 3
Phase 2 Archived Models
Manufacturer |
Model |
Fuel Type |
Maximum Heat Output Rating (BTU/hr) |
8-hour Output |
Annual Average Efficiency (% HHV) |
Annual Avg Emission Rate (grams/hr) |
Annual Avg Emission Level (lbs/million BTU) |
---|---|---|---|---|---|---|---|
Kunzel |
wood pellets; |
45506 |
NA |
0.7 |
0.21 |
||
Kunzel |
wood pellets; |
85969 |
NA |
1.2 |
0.13 |
||
E - Classic |
stick wood; |
209316 |
107459 |
NA |
5.5 |
0.27 |
|
E - Classic |
stick wood; |
172343 |
160001 |
NA |
6.4 |
0.31 |
|
E-Classic |
stick wood; |
260486 |
186453 |
NA |
3.3 |
0.12 |
|
Maxim |
wood pellets; |
212453 |
NA |
1.6 |
0.06 |
||
KBP 270 |
wood pellets; |
120000 |
NA |
2.96 |
0.20 |
||
200 SSR II |
stick wood; |
204934 |
66842 |
NA |
3.7 |
0.18 |
|
Earth |
stick wood; |
189093 |
87577 |
NA |
3.56 |
0.19 |
|
Northland Dist. & Mfg Inc. |
Pristine Series 1000 |
stick wood; |
82968 |
48721 |
NA |
2.5 |
0.24 |
Northwest Manufacturing, Inc. (Woodmaster) |
AFS 900 |
wood pellets; |
107069 |
NA |
2.49 |
0.24 |
|
Pro-Fab Industries |
Empyre |
stick wood; |
219278 |
66290 |
NA |
8.4 |
0.27 |
Pro-Fab Industries |
Empyre |
stick wood; |
209119 |
177333 |
NA |
6.1 |
0.31 |
Wood Doctor |
WD- |
stick wood; |
248411 |
112655 |
NA |
6.1 |
0.26 |