Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

    • Environmental Topics
    • Air
    • Bed Bugs
    • Cancer
    • Chemicals, Toxics, and Pesticide
    • Emergency Response
    • Environmental Information by Location
    • Health
    • Land, Waste, and Cleanup
    • Lead
    • Mold
    • Radon
    • Research
    • Science Topics
    • Water Topics
    • A-Z Topic Index
    • Laws & Regulations
    • By Business Sector
    • By Topic
    • Compliance
    • Enforcement
    • Laws and Executive Orders
    • Regulations
    • Report a Violation
    • Environmental Violations
    • Fraud, Waste or Abuse
    • About EPA
    • Our Mission and What We Do
    • Headquarters Offices
    • Regional Offices
    • Labs and Research Centers
    • Planning, Budget, and Results
    • Organization Chart
    • EPA History

Breadcrumb

  1. Home
  2. Significant New Alternatives Policy (SNAP)

Substitutes in Remote Condensing Units

Substitutes are reviewed on the basis of environmental and health risks, including factors such as ozone depletion potential, global warming potential, toxicity, flammability, and exposure potential. Lists of acceptableThis designation means that a substitute may be used, without restriction, to replace the relevant ODS within the end-use specified. For example, HCFC-22 is an acceptable substitute for R-502 in industrial process refrigeration. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. and unacceptableThis designation means that it is illegal to use a product as a substitute for an ODS in a specific end-use. For example, HCFC-141b is an unacceptable substitute for CFC-11 in building chillers. Note that all SNAP determinations apply to the use of a specific product as a substitute for a specific ODS in a specific end-use. substitutes are updated several times each year. The list of substitutes is shown below.

Many acceptable substitutes under SNAP may be restricted under the Technology Transitions Program. For more information on Technology Transitions Program restrictions, visit: https://www.epa.gov/climate-hfcs-reduction/technology-transitions-program

Note: SNAP-related information published in the Federal Register takes precedence over all information on this page.

Filters              
Substitute Trade Name(s) Retrofit/New ODPA number that refers to the amount of ozone depletion caused by a substance. The ODP is the ratio of the impact on ozone of a chemical compared to the impact of a similar mass of CFC-11. Thus, the ODP of CFC-11 is defined to be 1.0. Other CFCs and HCFCs have ODPs that range from 0.01 to 1.0. The halons have ODPs ranging up to 10. Carbon tetrachloride has an ODP of 1.2, and methyl chloroform's ODP is 0.11. HFCs have zero ODP because they do not contain chlorine. A table of all ozone-depleting substances (https://www3.epa.gov/ozone/science/ods/index.html) shows their ODPs, GWPs, and CAS numbers. GWPThe index used to translate the level of emissions of various gases into a common measure in order to compare the relative radiative forcing of different gases without directly calculating the changes in atmospheric concentrations. GWPs are calculated as the ratio of the radiative forcing that would result from the emissions of one kilogram of a greenhouse gas to that from the emission of one kilogram of carbon dioxide over a period of time (usually 100 years). Gases involved in complex atmospheric chemical processes have not been assigned GWPs. See lifetime. ASHRAE
Designation
(Safety
Classification)
SNAP Listing Date Listing Status
Ammonia Vapor Compression with Secondary Loop   N 0 0 B2 March 18, 1994;
September 5, 1996
Acceptable
FOR12A FOR12A R/N 0 1,100 A1 December 18, 2000 (pdf) (257 KB) Acceptable
FOR12B FOR12B R/N 0 1,000 A1 December 18, 2000 (pdf) (257 KB) Acceptable
RB-276 Free Zone, HCFC Blend Delta R/N 0.013 1,592 A1 September 5, 1996 Acceptable
Freeze 12 Freeze 12 R/N 0.013 1,606 A1 September 5, 1996 Acceptable
R-416A FRIGC FR-12, HCFC Blend Beta R/N 0.009 1,081 A1 February 8, 1996 (pdf) (151 KB);
February 24, 1998 (pdf) (140 KB)
Acceptable
G2018C G2018C R/N 0.053 1,731 A1 September 5, 1996 Acceptable
GHG-HP HCFC Blend Lambda R/N 0.056 1,893 A1 February 8, 1996 (pdf) (151 KB) Acceptable
R-414A GHG-X4, Autofrost, Chill-it, HCFC Blend Xi R/N 0.045 1,478 A1 September 5, 1996 Acceptable
GHG-X5 GHG-X5 R/N 0.032 2,377 A1 June 3, 1997 (pdf) (133 KB) Acceptable
HCFC-22   R/N 0.055 1,810 A1 March 18, 1994 Acceptable
HCFC-22/HCFC-142b   R/N 0.055-0.065 1,810-2,310 A1 June 3, 1997 (pdf) (133 KB) Acceptable
HFC-134a   R/N 0 1,430 A1 March 18, 1994 Acceptable
HFC-134a/HBr (92/8)   N 0.0016 N/A A1 May 23, 2001 (pdf) (144 KB) Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements.
HFC-227ea   N 0 3,220 A1 March 18, 1994;
July 20, 2015 (pdf) (686 KB)
Unacceptable in new equipment as of January 1, 2017.
HFE-449s1 (methoxynonafluorobutane, iso and normal) Novec™ 7100 Engineered Fluid (HFE-7100) N 0 297 A1 December 18, 2000 (pdf) (257 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.
HFE-569sf2 (ethoxynonafluorobutane, iso and normal) Novec™ 7200 Engineered Fluid (HFE-7200) N 0 59 N/A December 18, 2000 (pdf) (257 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems.
R-414B Hot Shot, Kar Kool, HCFC Blend Omicron R/N 0.098 3,337 A1 September 5, 1996 Acceptable
R-417C Hot Shot 2 R 0 1,820 A1 October 4, 2011 (pdf) (200 KB) Acceptable
Ikon A Ikon-12, Blend Zeta R/N 0 N/A A1 June 19, 2000 (pdf) (223 KB) Acceptable
Ikon B   R/N 0 N/A A1 December 6, 1999 (pdf) (225 KB) Acceptable
R-125/R-290/R-134a/R-600a (55.0/1.0/42.5/1.5) ICOR AT-22 R/N 0 2,530 A1 June 16, 2010 (pdf) (229 KB) Acceptable
R-401A SUVA MP-39 N 0.037 1,182 A1 January 13, 1995 (pdf) (185 KB) Acceptable
R-401B SUVA MP-66 N 0.040 1,288 A1 January 13, 1995 (pdf) (185 KB) Acceptable
R-402A HP-80 R/N 0.019 2,746 A1 March 18, 1994 Acceptable
R-402B HP-81 R/N 0.03 2,379 A1 March 18, 1994 Acceptable
R-404A SUVA HP-62 R/N 0 3,920 A1 March 18, 1994;
December 20, 2002 (pdf) (168 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-406A GHG-12, GHG-X3, McCool, Autofrost X3 R 0.057 1,900 A2 August 26, 1994 Acceptable
R-407A Klea 60, Klea 407A R/N 0 2,110 A1 August 26, 1994;
January 2, 2009 (pdf) (173 KB)
Acceptable
R-407B Klea 61 R/N 0 2,800 A1 August 26, 1994;
June 16, 2010 (pdf) (229 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-407C Suva 407C, Klea 407C R/N 0 1,770 A1 February 8, 1996  (pdf) (151 KB);
December 20, 2002 (pdf) (168 KB);
August 21, 2003 (pdf) (160 KB)
Acceptable
R-407F  Genetron Performax LT R/N 0 1,820 A1 October 4, 2011 (pdf) (200 KB) Acceptable
R-407H   R/N 0 1,500 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-408A  HCFC Blend Epsilon R 0.026 3,152 A1 August 26, 1994 Acceptable
R-409A  HCFC Blend Gamma R 0.047 1,558 A1 August 26, 1994 Acceptable
R-410A AZ-20, Suva 9100, Puron N 0 2,090 A1 February 8, 1996 (pdf) (151 KB);
December 20, 2002 (pdf) (168 KB)
Acceptable
R-410B   N 0 2,230 A1 February 8, 1996 (pdf) (151 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-411A   R/N 0.048 1,600 A2 February 8, 1996 (pdf) (151 KB) Acceptable
R-411B   R/N 0.052 1,700 A2 February 8, 1996 (pdf) (151 KB) Acceptable
R-417A ISCEON 59, NU-22 R/N 0 2,350 A1 December 6, 1999 (pdf) (225 KB);
December 20, 2002 (pdf) (168 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-420A Choice R-420A R/N 0.008 1,536 A1 October 1, 2004 (pdf) (186 KB) Acceptable
R-421A Choice R-421A R/N 0 2,630 A1 September 28, 2006 (pdf) (182 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-421B Choice R-421B R/N 0 3,190 A1 September 28, 2006 (pdf) (182 KB);
June 16, 2010 (pdf) (229 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-422A ISCEON 79 R/N 0 3,140 A1 October 1, 2004 (pdf) (186 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-422B ICOR XAC1, NU-22B R/N 0 2,530 A1 March 29, 2006 (pdf) (181 KB) Acceptable
R-422C ICOR XLT1 R/N 0 3,390 A1 March 29, 2006 (pdf) (181 KB);
June 16, 2010 (pdf) (229 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-422D ISCEON MO29 R/N 0 2,730 A1 September 28, 2006 (pdf) (182 KB);
June 16, 2010 (pdf) (229 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-424A RS-44 R/N 0 2,440 A1 September 28, 2006 (pdf) (182 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-426A RS-24 R/N 0 1,510 A1 September 28, 2006 (pdf) (182 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-427A Forane® 427A R 0 2,140 A1 January 2, 2009 (pdf) (173 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-428A RS-52 R/N 0 3,610 A1 October 4, 2007 (pdf) (163 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-434A RS-45 R/N 0 3,250 A1 October 4, 2007 (pdf) (163 KB);
June 16, 2010 (pdf) (229 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-437A KDD6, ISCEON MO49 Plus R/N 0 1,810 A1 January 2, 2009 (pdf) (173 KB) Acceptable
R-438A KDD5, ISCEON MO99 R/N 0 2,270 A1 October 4, 2007 (pdf) (163 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
R-442A RS-50 R/N 0 1,890 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-471A Solstice® N71 R/N 0 144 A1

September 8, 2023 (pdf) (246 KB)

December 11, 2024 (pdf) (300 KB)

Acceptable
R-515B Solstice® N15 N 0 287 A1 September 8, 2023 (pdf) (246 KB) Acceptable
R-452A Opteon™ XP44 R/N 0 2,140 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-452C Forane® 452C R/N 0 2,200 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-453A RS-70 R/N 0 1,770 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-458A Bluon TdX 20 R/N 0 1,650 A1 July 21, 2017 (pdf) (314 KB) Acceptable
R-507, R-507A AZ-50 R/N 0 3,990 A1 March 18, 1994;
December 20, 2002 (pdf) (168 KB);
September 30, 2009 (pdf) (172 KB);
July 20, 2015 (pdf) (686 KB)
Unacceptable in retrofit equipment as of July 20, 2016.

Unacceptable in new equipment as of January 1, 2018.
R-513A Opteon™ XP 10 R/N 0 630 A1 July 16, 2015 (pdf) (353 KB) Acceptable
R-744 (Carbon Dioxide, CO2)   N 0 1 A1 September 30, 2009 (pdf) (172 KB) Acceptable
RS-24 (2002 formulation)   R/N 0 1,510 A1 December 20, 2002 (pdf) (168 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
RS-44 (2003 formulation)   R/N 0 2,420 A1 June 16, 2010 (pdf) (229 KB) Acceptable
Self-chilling cans using CO2   N 0 1 A1 February 24, 1998 (pdf) (140 KB) Acceptable
SP34E SP34E R/N 0 <1,470 A1 December 18, 2000 (pdf) (257 KB);
June 16, 2010 (pdf) (229 KB)
Acceptable
THR-02   R/N 0 N/A A1 December 6, 1999 (pdf) (225 KB) Acceptable
THR-03   R/N 0 N/A A1 December 6, 1999 (pdf) (225 KB) Acceptable
THR-04   R/N >0 N/A A1 June 8, 1999 (pdf) (142 KB) Acceptable
R-450A Solstice® N-13 R/N 0 601 A1 October 21, 2014 (pdf) (345 KB) Acceptable
R-448A Solstice® N-40 R/N 0 1,387 A1 July 16, 2015 (pdf) (353 KB) Acceptable
R-449A Opteon™ XP 40 R/N 0 1,400 A1 July 16, 2015 (pdf) (353 KB) Acceptable
R-449B Forane® 449B R/N 0 1,412 A1 October 11, 2016 (pdf) (284 KB) Acceptable
R-513A Opteon™ XP 10 R/N 0 630 A1 July 16, 2015 (pdf) (353 KB) Acceptable
HFO-1234yf   N 0 1 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
HFO-1234ze(E)   N 0 1 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
R-454A Opteon™ XL40 N 0 237 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
R-454C Opteon™ XL20 N 0 146 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
R-455A Solstice® L40X N 0 146 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
R-457A Forane® 457A N 0 137 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.
R-516A Forane® 516A N 0 140 A2L June 13, 2024 (pdf) (1,207 KB) Acceptable subject to use conditions: See rule for detailed conditions.

Back to the Refrigeration and Air Conditioning sector page.

Contact Us to ask a question, provide feedback, or report a problem.
Last updated on April 23, 2025
  • Assistance
  • Spanish
  • Arabic
  • Chinese (simplified)
  • Chinese (traditional)
  • French
  • Haitian Creole
  • Korean
  • Portuguese
  • Russian
  • Tagalog
  • Vietnamese
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshot
  • Grants
  • No FEAR Act Data
  • Plain Writing
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions
  • Site Feedback

Follow.