Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

    • Environmental Topics
    • Air
    • Bed Bugs
    • Cancer
    • Chemicals, Toxics, and Pesticide
    • Emergency Response
    • Environmental Information by Location
    • Health
    • Land, Waste, and Cleanup
    • Lead
    • Mold
    • Radon
    • Research
    • Science Topics
    • Water Topics
    • A-Z Topic Index
    • Laws & Regulations
    • By Business Sector
    • By Topic
    • Compliance
    • Enforcement
    • Laws and Executive Orders
    • Regulations
    • Report a Violation
    • Environmental Violations
    • Fraud, Waste or Abuse
    • About EPA
    • Our Mission and What We Do
    • Headquarters Offices
    • Regional Offices
    • Labs and Research Centers
    • Planning, Budget, and Results
    • Organization Chart
    • EPA History

Breadcrumb

  1. Home
  2. Water Reuse

Summary of Pennsylvania's Water Reuse Guideline or Regulation for Potable Water Reuse

This page is part of the EPA’s REUSExplorer tool, which summarizes the different state level regulations or guidelines for water reuse for a variety of sources and end-uses.
The source water for this summary is Treated Municipal Wastewater.

REUSExplorer Links
  • REUSExplorer home page
  • News in reuse regulations
  • Maps of states with water reuse regulations or guidelines

On this page:

  • Technical basis
  • Types of planned potable reuse approved for use in Pennsylvania
  • Water reuse treatment category type
  • Potable reuse specifications (table)
  • Upcoming state law or policy
  • References
  • Disclaimer

This page is a summary of the state’s water reuse law or policy and is provided for informational purposes only. Please always refer to the state for the most accurate and updated information. 

In Pennsylvania, potable water reuse The use of highly treated recycled water for drinking water purposes. This reuse application includes both indirect potable reuse through introduction of recycled water into an environmental buffer such as a surface reservoir or groundwater aquifer, and direct potable reuse through introduction of recycled water into a drinking water system. applications include indirect potable reuse (surface water spreading and groundwater recharge). The source of water treated municipal wastewater Treated wastewater effluent discharged from a centralized wastewater treatment plant of any size. Other terms referring to this source of water include domestic wastewater, treated wastewater effluent, reclaimed water, and treated sewage. is specified by the state as municipal wastewater. The write-up uses state terms when discussing sources or uses of water that may differ from the Regulations and End-Use Specifications Explorer's (REUSExplorer's) terms.

Technical basis

Potable water in the United States must meet all applicable Safe Drinking Water Act (SDWA) requirements, including its implementing regulations (40 C.F.R. § 141) for chemical and microbial contaminants and pollutant discharges from a point source for surface water augmentation require a federal National Pollutant Discharge Elimination Systems (NPDES) permit (40 C.F.R. § 122). Pennsylvania does not have state statutes or regulations that specifically address the reuse of treated wastewater, however, water reuse in Pennsylvania is implemented through the technical guidance manual and Water Quality Management permits (Pennsylvania DEP, 2012). If the reclaimed water is used for direct injection, certain requirements of EPA’s Underground Injection Control Program (U.S. EPA, 2021) may need to be met. Additionally, Pennsylvania indirect potable reuse guidelines require specific treatment requirements, which vary by the class of reclaimed water.

For chemicals, Pennsylvania reuse guidelines require class A+ finished water meet a less than 1 mg/L total organic carbon (TOC) concentration. The guidelines require that class A reclaimed water have less than 10 mg/L total organic carbon (TOC) concentration. The technical basis for the removal of microbial and chemical contaminants is not explicitly specified.

Types of planned potable reuse approved for use in Pennsylvania

Pennsylvania DEP (2012) defines the following approved planned potable uses:

  • Indirect potable reuse
    • Surface water spreading (Class A) – augmentation or recharge to potable (or non-potable) water aquifers via surface spreading.
    • Groundwater recharge
      • Direct injection (Class A+) – augmentation or recharge to potable (or non-potable) water aquifers, or salt water intrusion barriers.

Water reuse treatment category/type

The various classes of reclaimed water are defined by their respective treatment requirements and applicable performance standards. Treatment requirements for various classes of water for indirect potable reuse applications include:

  • For Class A reclaimed water, the minimum treatment is secondary treatment, nitrification, denitrification, filtration and disinfection. Reclaimed water should be retained underground for a minimum of 9 months prior to withdrawal in aquifers used as drinking water sources (Pennsylvania DEP, 2012).
    • In cases where UV light is used for disinfection, a dose of ≥100 mJ/cm2 is required. 
    • In cases where chlorine is used for disinfection, a total chlorine residual of at least 1.0 mg/L should be maintained for a minimum contact time of 30 minutes at design average flow.
  • For Class A+ reclaimed water, the minimum treatment is secondary treatment, nitrification, denitrification, coagulation, filtration, reverse osmosis treatment, disinfection and any other advanced treatment processes necessary to meet standards (listed in table, Summary of Pennsylvania’s Potable Reuse Specifications). Reclaimed water should be retained underground for a minimum of 12 months prior to withdrawal in aquifers used as drinking water sources (Pennsylvania DEP, 2012).
    • In cases where UV light is used for disinfection, a dose of ≥50 mJ/cm2 is required. 
    • In cases where chlorine is used for disinfection, a total chlorine residual of at least 1.0 mg/L should be maintained for a minimum contact time of 30 minutes at design average flow.

Potable reuse specifications

Summary of Pennsylvania's Potable Reuse Specifications

Recycled Water Class/Category Source Water Type Water Quality Parameter Specification Sampling/Monitoring Requirements (Frequency of monitoring; site/ location of sample; quantification methods)

Class A+ Reclaimed Water

Municipal wastewater

Biochemical oxygen demand (BOD)

<2 mg/L (monthly average)

5 mg/L (maximum)

Monitoring 2/week

Total organic carbon (TOC)

< 1 mg/L

Monitoring 2/week

Turbidity

≤ 0.3 NTU (monthly average)

1 NTU (maximum)

Continuous monitoring

Fecal coliform

<2.2 organisms per 100 mL (monthly average)

23 organisms per 100 mL (maximum)

Monitoring 2/week

Total organic halides (TOX)

<0.2 mg/L (monthly average)

Monitoring 2/week

Total nitrogen

<10 mg/L (monthly average)

Monitoring 2/week

All other primary and secondary drinking water contaminants

See SDWA regulations (40 C.F.R. § 141)

Quarterly monitoring

UV light design doseb

≥ 50 mJ/cm2

Continuous monitoring of lamp intensity, UV transmittance and flow rate

Class A Reclaimed Water

Municipal wastewater

Biochemical oxygen demand (BOD)

<2 mg/L (monthly average)

5 mg/L (maximum)

Weekly monitoring

Total organic carbon (TOC)

<10 mg/L

Weekly monitoring

Turbidity

≤ 2 NTU (monthly average)

5 NTU (maximum)

Continuous monitoring

Fecal coliform

<2.2 organisms per 100 mL (monthly average)

23 organisms per 100 mL (maximum)

Monitoring 2/week

Total organic halides (TOX)

<0.2 mg/L (monthly average)

Weekly monitoring

Total nitrogen

<10 mg/L (monthly average)

Weekly monitoring

All other primary and secondary drinking water contaminants

See SDWA regulations (40 C.F.R. § 141)

Quarterly monitoring

Total chlorine residuala

≥1.0 mg/L (maintained for a minimum contact time of 30 minutes at design average flow)

>0.02 mg/L (at the point of reuse application)

Continuous on-line monitoring

UV light design doseb

≥ 100 mJ/cm2 (for granular media filtration)

≥ 80 mJ/cm2 (for porous membrane filtration)

≥ 50 mJ/cm2 (for semi-permeable membrane filtration)

Continuous monitoring of lamp intensity, UV transmittance and flow rate

Sources =  Pennsylvania DEP, 2012.

a Only applies if chlorine was used for disinfection.

b Only applies if UV light was used for disinfection.

Upcoming state law or policy

No upcoming potable reuse regulations were noted for Pennsylvania.

References:

EPA-Administered Permit Programs: The National Pollutant Discharge Elimination System, 40 C.F.R. § 122.

National Primary Drinking Water Regulations, 40 C.F.R. § 141.

Pennsylvania Department of Environmental Protection (DEP). 2012. Point and Nonpoint Source Management. Reuse of treated wastewater guidance manual 385-2188-002.

U.S. Environmental Protection Agency (U.S. EPA). 2021. Protecting Underground Sources of Drinking Water from Underground Injection (UIC).


Disclaimers

Disclaimers

The Regulations and End-Use Specifications Explorer (REUSExplorer) is intended to be a synthesis of state laws and policies governing water reuse across the US for informational purposes only. These summaries are not legally binding and do not replace or modify any state or federal laws. In the case of any conflict between these summaries and a state or federal law, the state or federal law governs. Numeric and other types of water reuse standards and specification regulations are included in these summaries, but not necessarily all relevant state laws. It is possible a state law authorizes types of water reuse, while no reuse standards and/or specification regulations have been adopted.

Inclusion/Exclusion Criteria

References were included if they could be categorized as either an act, standard, regulation, criteria, guideline, guidance document, technical manual, or appendix issued by a government, standards organization (e.g., ISO, NSF/ANSI), professional association (e.g., AWWA, IWA), research sponsor (e.g., WERF, WRF), or expert committee (e.g., National Academies) and considered to be active or adopted. References were excluded if they indicated that a state approved reuse projects on a case-by-case basis only; contained no water quality specifications or requirements; and/or focused on land disposal of both water and biosolids rather than a specific reuse application.

Please contact us at waterreuse@epa.gov if the information on this page needs updating or if this state is updating or planning to update its laws and policies and we have not included that information on the news page.

Contact Us to ask a question, provide feedback, or report a problem.
Last updated on February 10, 2025
  • Assistance
  • Spanish
  • Arabic
  • Chinese (simplified)
  • Chinese (traditional)
  • French
  • Haitian Creole
  • Korean
  • Portuguese
  • Russian
  • Tagalog
  • Vietnamese
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshot
  • Grants
  • No FEAR Act Data
  • Plain Writing
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions
  • Site Feedback

Follow.