Science & Technology
-
RFC: 11702 Perchlorate Advisory Levels
Submitted by George Seaver
-
EPA response to Appeal to RFC: 11702 Perchlorate Advisory Levels
EPA response to the Request for Correction (RFC)
-
Previous Federal Agency Hazardous Waste Compliance Docket Updates
The Federal Agency Hazardous Waste Compliance Docket contains information reported to EPA by federal facilities that manage hazardous waste or from which hazardous substances, pollutants, or contaminants have been - or may be - released.
-
Phosphogypsum
Phosphogypsum is a solid waste byproduct from processing phosphate ore to make phosphoric acid that is later used in fertilizer. The phosphate ore and the resulting phosphogypsum contain radium, which decays to form radon gas. Both radium and radon are rad
-
Interim Guidance on the Destruction and Disposal of PFAS and Materials Containing PFAS
This 2026 update of the U.S. Environmental Protection Agency (EPA) interim guidance presents currently available information on the destruction and disposal of perfluoroalkyl and polyfluoroalkyl substances (PFAS) and PFAS-containing materials.
-
EPA Method 5035A (SW-846): Closed-System Purge-and-Trap and Extraction for Volatile Organics in Soil and Waste Samples
SAM lists this method for preparation of solid samples to be analyzed for select VOCs, using purge-and-trap GC.
-
EPA IO [Inorganic] Compendium Method IO-3.4: Determination of Metals in Ambient Particulate Matter Using Inductively Coupled Plasma (ICP) Spectroscopy
This method describes procedures for analysis of compounds containing arsenic, osmium, thallium or vanadium in prepared air samples, using ICP-AES.
-
EPA Method 8290A, Appendix A (SW-846): Procedure for the Collection, Handling, Analysis, and Reporting of Wipe Tests Performed Within the Laboratory
This method provides procedures for detection and measurement of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in a variety of environmental matrices.
-
EPA IO [Inorganic] Compendium Method IO-5: Sampling and Analysis for Vapor and Particle Phase Mercury in Ambient Air Utilizing Cold Vapor Atomic Fluorescence Spectrometry (CVAFS)
This method describes procedures for preparation and analysis of air samples for vapor and particulate mercury using acid digestion and cold vapor atomic fluorescence spectrometry.
-
EPA Air Method, Toxic Organics - 10A (TO-10A): Determination of Pesticides and Polychlorinated Biphenyls in Ambient Air Using Low Volume Polyurethane Foam (PUF) Sampling Followed by Gas Chromatographic/Multi-Detector Detection (GC/MD)
This method describes procedures for preparation and analysis of air samples for detection and measurement of select organic compounds, using solvent extraction and GC-MS.
-
EPA Method 3135.2I: Cyanide, Total and Amenable in Aqueous and Solid Samples Automated Colorimetric With Manual Digestion
This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.
-
EPA IO [Inorganic] Compendium Method IO-3.5: Determination of Metals in Ambient Particulate Matter Using Inductively Coupled Plasma/Mass Spectrometry (ICP-MS)
This method describes procedures for analysis of prepared air samples for detection and measurement of metal compounds as the total metal, using ICP-MS.
-
EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection-Liquid Chromatography/Tandem Mass Spectrometry (DAI-LC/MS/MS)
EPA’s Selected Analytical Methods for Environmental Remediation and Recovery (SAM) lists this method for preparation and analysis of drinking water samples to detect and measure acephate, diisopropyl methylphosphonate (DIMP), methamidophos and thiofanox.
-
EPA Method 8316 (SW-846): Acrylamide, Acrylonitrile and Acrolein by High Performance Liquid Chromatography (HPLC)
This method describes procedures for analysis of acrylamide, acrylonitrile and acrolein in water samples, using HPLC-UV detection.
-
EPA Method 525.2: Determination of Organic Compounds in Drinking Water by Liquid-Solid Extraction and Capillary Column Gas Chromatography/Mass Spectrometry
SAM lists this method for preparation and analysis of water samples for selected organic compounds using liquid-solid or solid-phase extraction and GC-MS.
-
EPA Method 8318A (SW-846): N-Methylcarbamates by High Performance Liquid Chromatography (HPLC)
This method describes procedures for preparation and analysis of solid samples for methylcarbamates using solvent extraction and HPLC-FL detection.
-
EPA Regional Contacts for Water Reuse
List of individuals serving as water reuse contacts for their EPA Region.
-
EPA Method 5030C (SW-846): Purge-and-Trap for Aqueous Samples
SAM lists this method for preparation of water samples to be analyzed for select volatile organic compounds, using purge-and-trap GC.
-
EPA Method 8260D (SW-846): Volatile Organic Compounds by Gas Chromatography-Mass Spectrometry (GC/MS)
This method provides procedures for analysis of solid, water and wipe samples to detect and measure selected volatile organic compounds, using purge-and-trap GC-MS.
-
OSHA Method PV2004: Acrylamide
This method describes procedures for preparation and analysis of air samples for detection and measurement of acrylamide, using by solvent desorption and HPLC.