Confirm that ASTM method D-1319, Fluorescent Indicator Adsorption (FIA) can be used to determine aromatic and olefin levels until January 1, 1997.
Yes, the current version, ASTM method D-1319-93, is the regulatory method for olefins and may be used as an alternate for aromatics until January 1, 1997. For aromatics, it must also be correlated to the GC-MS method. Correlation to another laboratory's GC-MS is acceptable. Each D-1319 analysis system must show correlation since the method is operator dependent.(7/1/94)
This question and answer was posted at Consolidated List of Reformulated Gasoline and Anti-Dumping Questions and Answers: July 1, 1994 through November 10, 1997 (PDF)(333 pp, 18.17 MB, EPA420-R-03-009, July 2003, About PDF)