Skip to main content
U.S. flag

An official website of the United States government

Here’s how you know

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock (LockA locked padlock) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

    • Environmental Topics
    • Air
    • Bed Bugs
    • Cancer
    • Chemicals, Toxics, and Pesticide
    • Emergency Response
    • Environmental Information by Location
    • Health
    • Land, Waste, and Cleanup
    • Lead
    • Mold
    • Radon
    • Research
    • Science Topics
    • Water Topics
    • A-Z Topic Index
    • Laws & Regulations
    • By Business Sector
    • By Topic
    • Compliance
    • Enforcement
    • Laws and Executive Orders
    • Regulations
    • Report a Violation
    • Environmental Violations
    • Fraud, Waste or Abuse
    • About EPA
    • Our Mission and What We Do
    • Headquarters Offices
    • Regional Offices
    • Labs and Research Centers
    • Planning, Budget, and Results
    • Organization Chart
    • EPA History

Breadcrumb

  1. Home
  2. Clean Water Act Analytical Methods

PCB Congeners by Low-Resolution GC-MS - Method 1628 (Not yet approved)

Method 1628 measures polychlorinated biphenyls (PCBs) in wastewater. This method is not yet approved at 40 CFR Part 136.

On this page:

  • Background
  • Multi-laboratory Validation Study
  • Description of Method
  • Conclusions
  • Status
  • Documents

Background

The only method currently approved at 40 CFR Part 136 for monitoring PCBs in wastewater is Method 608.3, which only targets seven common Aroclor mixtures. Because most PCB contamination in the environment is highly weathered and often does not resemble any of the Aroclor mixtures and there are non-Aroclor sources of PCB in the environment, Aroclor results are likely to underestimate PCB contamination or provide non-detects in a sample when compared to the analysis of individual PCB congeners. EPA sought to develop a new method that would meet the following goals:

  1. Identified and quantified PCBs using individual congeners, not Aroclors 
  2. Was more sensitive than Method 608.3, but not so sensitive that it is susceptible to background contamination issues
  3. Could be implemented at a typical mid-sized full-service environmental laboratory.

Multi-laboratory Validation Study

In 2020, the EPA’s Office of Water completed a multi-laboratory validation of Method 1628, a PCB congener method using low-resolution gas chromatography - mass spectrometry with selected ion monitoring (GC-MS-SIM). The study involved 12 laboratories and 4 matrices. EPA has developed a multi-laboratory validation study report and accompanying method.

Description of Method

Method 1628 detects all 209 PCB congeners and quantifies them either directly or indirectly. A total of 29 carbon-13 labeled PCB congeners are used as isotope dilution quantification standards. An additional 19 congeners are quantified by an extracted internal standard procedure, using one of the isotope dilution standards. The remaining 144 congeners are quantified against a labeled standard in the same homolog. This approach strikes a balance between enabling the laboratory to detect and quantify all 209 congeners, while not making the method too arduous. Method performance was similar across all the congeners, regardless of the quantification approach.

The primary focus of this new method is on wastewater compliance monitoring, but there is a need for testing biosolids, soils/sediments, and fish tissue as well. Therefore, the multi-laboratory study tested:

  • Nine aqueous sample types, including wastewater effluents and influents collected from publicly owned treatment work and indirect industrial dischargers
  • Three sediments
  • Three biosolids collected from municipal wastewater treatment plants
  • Fish tissues from three species.

Conclusions

The EPA met its goals and has demonstrated that Method 1628 is effective in all the matrices tested. It provides better quality control information to support data quality assessments, is more sensitive than the currently approved Method 608.3, but not so sensitive that blank contamination is a problem, and can be easily implemented at a typical full-service environmental laboratory. The EPA’s only other PCB congener method uses high-resolution mass spectrometry instrumentation, which many full-service laboratories do not own. Therefore, Method 1628 provides access to PCB congener analysis to any laboratory using a typical gas chromatograph/mass spectrometer (GC/MS) instrument that is used for many other EPA methods.

Status

Method 1628 is not yet approved at 40 CFR Part 136 for use in Clean Water Act compliance monitoring. The method would need to be proposed and promulgated in a future rulemaking to become an approved method. However, having completed a multi-laboratory validation study, the EPA considers the method suitable for release to laboratories, regulators, regulated industries, and the general public. States authorized to issue NPDES permits may elect to use this method in permits, pending nationwide approval by the EPA.

Documents

Method 1628: Polychlorinated Biphenyl (PCB) Congeners in Water, Soil, Sediment, Biosolids, and Tissue by Low-resolution GC/MS using Selected Ion Monitoring (pdf) (1.4 MB, July 2021, 821-R-21-002)

Report on the Multi-laboratory Validation of Clean Water Act Method 1628 for PCB Congeners (pdf) (5.16 MB, April 2021, 820-R-21-003)

Clean Water Act Analytical Methods

  • PFAS Methods
  • Methods Update Rules
  • Approved Chemical Methods
    • Inorganic Non‑Metals
    • Metals
    • Organic
  • Approved Microbiological Methods
    • Wastewater & Sewage Sludge
    • Ambient Water
  • Approved WET Methods
    • Acute
    • Chronic - Freshwater
    • Chronic - Marine/Estuarine
  • Approved Radiochemical Methods
  • Approved Industry-Specific Methods
  • Other CWA Methods: Chemical
  • Other CWA Methods: Microbiological
  • Other CWA Methods: Biosolids
  • Alternate Test Procedures
  • Regulatory History
Contact Us about CWA Analytical Methods
Contact Us to ask a question, provide feedback, or report a problem.
Last updated on September 18, 2024
  • Assistance
  • Spanish
  • Arabic
  • Chinese (simplified)
  • Chinese (traditional)
  • French
  • Haitian Creole
  • Korean
  • Portuguese
  • Russian
  • Tagalog
  • Vietnamese
United States Environmental Protection Agency

Discover.

  • Accessibility Statement
  • Budget & Performance
  • Contracting
  • EPA www Web Snapshot
  • Grants
  • No FEAR Act Data
  • Plain Writing
  • Privacy
  • Privacy and Security Notice

Connect.

  • Data
  • Inspector General
  • Jobs
  • Newsroom
  • Regulations.gov
  • Subscribe
  • USA.gov
  • White House

Ask.

  • Contact EPA
  • EPA Disclaimers
  • Hotlines
  • FOIA Requests
  • Frequent Questions
  • Site Feedback

Follow.

Environmental Protection Agency logo
www.epa.gov Feedback Survey

Welcome! Please share your feedback on how we can make www.epa.gov work better for you.

A red asterisk (*) indicates a required field.

Success

Thank you. Your feedback has been received.

Error

alert message

Required Questions - page 1 of 2
question_55203_answer_01
*

400 characters allowed
Would you like to take two more minutes to answer more questions to help us improve our services?
Yes, keep going →
← Back
Optional questions - page 2 of 2
How would you describe yourself?
400 characters allowed
400 characters allowed
400 characters allowed
U.S. flag

An official form of the United States government. Provided by Touchpoints
OMB Approval #1090-0008 · Expiration Date 11/30/2027